Databases in X2 series balances
In new PS.X2 series balances the information system is based on 7 databases which allow several users to work with database storing several products. The registered weighing results can be subject to further analysis.
The data is registered in 7 databases:
- Users (up to 10 users),
- Products (up to 5 000 products),
- Weighments (up to 50 000 weighments),
- Packaging (up to 100 packaging types),
- Formulas (up to 100 formulas),
- Clients (up to 1000 clients),
- ALIBI memory (up to 512 000 weighments).
The X2 series features option of making reports on formulas (up to 500 reports).
ALIBI Memory
The X2 series balances feature ALIBI memory that is a warranty for safety and automatic recording of your measurements. Options such as data preview, copying and archiving are available to users as well. The ALIBI memory allows to record up to 500 000 weighment records.
Personalization taken to the next level
The X2 is the only balance available on the market that provides a user with the option to design display using wide selection of widgets. Customised display of X2 series offers direct access to the results of your work and other important information directly from the home screen.
Weighing Data Management
USB interface facilitates quick transfer and copying of any results of your work (measurements, reports, databases) to other balances.Network management of the weighing data increases effectivity, productivity and safety of the important data to the maximum.
TECHNICAL FEATURES
PS 200/2000.X2 | PS 210.X2 | PS 360.X2 | PS 600.X2 | PS 750.X2 | PS 1000.X2 | PS 3000.X2 | PS 2100.X2.M | PS 3500.X2.M | PS 4500.X2.M | PS 6100.X2.M | PS 8100.X2.M | PS 10100.X2.M | |
Maximum capacity [Max] | 200 g / 2000 g | 210 g | 360 g | 600 g | 750 g | 1000 g | 3000 g | 2100 g | 3500 g | 4500 g | 6100 g | 8100 g | 10100 g |
Minimum load | 0.02 g | 0.02 g | 0.02 g | 0.02 g | 0.02 g | 0.02 g | 0.02 g | 0.5 g | 0.5 g | 0.5 g | 0.5 g | 0.5 g | 0.5 g |
Readability [d] | 0.001 g / 0.01 g | 0.001 g | 0.001 g | 0.001 g | 0.001 g | 0.001 g | 0.001 g | 0.01 g | 0.01 g | 0.01 g | 0.01 g | 0.01 g | 0.01 g |
Verification scale interval [e] | 0.01 g / 0.1 g | 0.01 g | 0.01 g | 0.01 g | 0.01 g | 0.01 g | — | 0.1 g | 0.1 g | 0.1 g | 0.1 g | 0.1 g | – |
Tare range | – 2000 g | – 210 g | – 360 g | –600 g | –750 g | –1000 g | –3000 g | –2100 g | – 3500 g | –4500 g | –6100 g | –8100 g | –10100 g |
Repeatability (5% Max)* | 0.0005 / 0.005 g | 0.0005 g | 0.0005 g | 0.0005 g | 0,0005 g | 0.0005 g | 0.0005 g | 0.005 g | 0.005 g | 0.005 g | 0.005 g | 0.005 g | 0.005 g |
Repeatability (Max) | 0.001 / 0.01 g | 0.001 g | 0.001 g | 0.0015 g | 0.0015 g | 0.0015 g | 0.0015 | 0.008 g | 0.008 g | 0.008 g | 0.008 g | 0.01 g | 0.012 g |
Linearity | ±0.002 g / ±0.02 g | ±0.002 g | ±0.002 g | ±0.003 g | ±0.003 g | ±0.003 g | ±0.004 g | ±0.02 g | ±0.02 g | ±0.02 g | ±0.02 g | ±0.03 g | ±0.03 g |
Sensitivity temperature drift** | 2 × 10-6 / °C × Rt | 2 × 10-6 / °C × Rt | 2 × 10-6 / °C × Rt | 2 × 10-6 / °C × Rt | 2 × 10-6 / °C × Rt | 2 × 10-6 / °C × Rt | 2 × 10-6 / °C × Rt | 2 × 10-6 / °C × Rt | 2 × 10-6 / °C × Rt | 2 × 10-6 / °C × Rt | 2 × 10-6 / °C × Rt | 2 × 10-6 / °C × Rt | 2 × 10-6 / °C × Rt |
Minimum weight (U=1%, k=2) | 0.1 g | 0.1 g | 0.1 g | 0.1 g | 0.1 g | 0.1 g | 0.1 g | 1 g | 1 g | 1 g | 1 g | 1 g | 1 g |
Minimum weight (USP) | 1 g | 1 g | 1 g | 1 g | 1 g | 1 g | 1 g | 10 g | 10 g | 10 g | 10 g | 10 g | 10 g |
Stabilization time | 2 s / 1.5 s | 2 s | 2 s | 2 s | 2 s | 2 s | 3 s | 1.5 s | 1.5 s | 1.5 s | 1.5 s | 1.5 s | 1.5 s |
Adjustment | internal | internal | internal | internal | internal | internal | internal | internal | internal | internal | internal | internal | internal |
Verification | Yes | Yes | Yes | Yes | Yes | Yes | — | Yes | Yes | Yes | Yes | Yes | – |
OIML Class | II | II | II | II | II | II | — | II | II | II | II | II | – |
Display | 5” capacitive colour touch screen | 5” capacitive colour touch screen | 5” capacitive colour touch screen | 5” capacitive colour touch screen | 5” capacitive colour touch screen | 5” capacitive colour touch screen | 5” capacitive colour touch screen | 5” capacitive colour touch screen | 5” capacitive colour touch screen | 5” capacitive colour touch screen | 5” capacitive colour touch screen | 5” capacitive colour touch screen | 5” capacitive colour touch screen |
Keypad | 6 keys | 6 keys | 6 keys | 6 keys | 6 keys | 6 keys | 6 keys | 6 keys | 6 keys | 6 keys | 6 keys | 6 keys | 6 keys |
Protection class | IP 43 | IP 43 | IP 43 | IP 43 | IP 43 | IP 43 | IP 43 | IP 43 | IP 43 | IP 43 | IP 43 | IP 43 | IP 43 |
Databases | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 | 7 |
Touch-free operation | 2 programmable proximity sensors | 2 programmable proximity sensors | 2 programmable proximity sensors | 2 programmable proximity sensors | 2 programmable proximity sensors | 2 programmable proximity sensors | 2 programmable proximity sensors | 2 programmable proximity sensors | 2 programmable proximity sensors | 2 programmable proximity sensors | 2 programmable proximity sensors | 2 programmable proximity sensors | 2 programmable proximity sensors |
USB-A | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
USB-B | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
RS 232 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Wi-Fi® | 802.11 b/g/n | 802.11 b/g/n | 802.11 b/g/n | 802.11 b/g/n | 802.11 b/g/n | 802.11 b/g/n | 802.11 b/g/n | 802.11 b/g/n | 802.11 b/g/n | 802.11 b/g/n | 802.11 b/g/n | 802.11 b/g/n | 802.11 b/g/n |
IN/OUT | 10 / 100 Mbit | 10 / 100 Mbit | 10 / 100 Mbit | 10 / 100 Mbit | 10 / 100 Mbit | 10 / 100 Mbit | 10 / 100 Mbit | 10 / 100 Mbit | 10 / 100 Mbit | 10 / 100 Mbit | 10 / 100 Mbit | 10 / 100 Mbit | 10 / 100 Mbit |
Power supply | 12 ÷ 16 V DC | 12 ÷ 16 V DC | 12 ÷ 16 V DC | 12 ÷ 16 V DC | 12 ÷ 16 V DC | 12 ÷ 16 V DC | 12 ÷ 16 V DC | 12 ÷ 16 V DC | 12 ÷ 16 V DC | 12 ÷ 16 V DC | 12 ÷ 16 V DC | 12 ÷ 16 V DC | 12 ÷ 16 V DC |
Power consumption | 4 W | 4 W | 4 W | 4 W | 4 W | 4 W | 4 W | 4 W | 4 W | 4 W | 4 W | 4 W | 4 W |
Operating temperature | +10 ÷ +40 °C | +10 ÷ +40 °C | +10 ÷ +40 °C | +10 ÷ +40 °C | +10 ÷ +40 °C | +10 ÷ +40 °C | +10 ÷ +40 °C | +10 ÷ +40 °C | +10 ÷ +40 °C | +10 ÷ +40 °C | +10 ÷ +40 °C | +10 ÷ +40 °C | +10 ÷ +40 °C |
Atmospheric humidity*** | 40 ÷ 80% | 40 ÷ 80% | 40 ÷ 80% | 40 ÷ 80% | 40 ÷ 80% | 40 ÷ 80% | 40 ÷ 80% | 40 ÷ 80% | 40 ÷ 80% | 40 ÷ 80% | 40 ÷ 80% | 40 ÷ 80% | 40 ÷ 80% |
Transport and storage temperature | –20 ÷ +50 °C | –20 ÷ +50 °C | –20 ÷ +50 °C | –20 ÷ +50 °C | –20 ÷ +50 °C | –20 ÷ +50 °C | –20 ÷ +50 °C | –20 ÷ +50 °C | –20 ÷ +50 °C | –20 ÷ +50 °C | –20 ÷ +50 °C | –20 ÷ +50 °C | –20 ÷ +50 °C |
Weighing pan dimensions | 128 × 128 mm | 128 × 128 mm | 128 × 128 mm | 128 × 128 mm | 128 × 128 mm | 128 × 128 mm | 128 × 128 mm | 195 × 195 mm | 195 × 195 mm | 195 × 195 mm | 195 × 195 mm | 195 × 195 mm | 195 × 195 mm |
Weighing pan material | stainless steel AISI 304 | stainless steel AISI 304 | stainless steel AISI 304 | stainless steel AISI 304 | stainless steel AISI 304 | stainless steel AISI 304 | stainless steel AISI 304 | stainless steel AISI 304 | stainless steel AISI 304 | stainless steel AISI 304 | stainless steel AISI 304 | stainless steel AISI 304 | stainless steel AISI 304 |
Weighing device dimensions | 333 × 206 × 100 mm | 333 × 206 × 100 mm | 333 × 206 × 100 mm | 333 × 206 × 100 mm | 333 × 206 × 100 mm | 333 × 206 × 100 mm | 333 × 206 × 100 mm | 333 × 206 × 100 mm | 333 × 206 × 100 mm | 333 × 206 × 107 mm | 333 × 206 × 107 mm | 333 × 206 × 107 mm | 333 × 206 × 107 mm |
Net weight | 3.9 kg | 3.7 kg | 3.7 kg | 3.9 kg | 3.9 kg | 3.9 kg | 3.9 kg | 4.3 kg | 4.5 kg | 4.5 kg | 4.5 kg | 4.5 kg | 4.5 kg |
Gross weight | 5.5 kg | 5.3 kg | 5.3 kg | 5.5 kg | 5.5 kg | 5.5 kg | 5.5 kg | 5.8 kg | 6 kg | 6.1 kg | 6.1 kg | 6.1 kg | 6.1 kg |
Packaging dimensions | 470 × 380 × 340 mm | 470 × 380 × 336 mm | 470 × 380 × 340 mm | 470 × 380 × 340 mm | 470 × 380 × 340 mm | 470 × 380 × 340 mm | 470 × 380 × 340 mm | 470 × 380 × 340 mm | 470 × 380 × 340 mm | 470 × 380 × 340 mm | 470 × 380 × 340 mm | 470 × 380 × 340 mm | 470 × 380 × 340 mm |
Rt net weight | |||||||||||||
* repeatability is expressed as a standard deviation from 10 weighing cycles | |||||||||||||
** parameter determined in the following temperature range: +15 ÷ +35 °C | |||||||||||||
*** optional solution on purchase order | |||||||||||||
**** non-condensing conditions |